Foundation Bolt Layout Design
Foundation Bolt Layout
1Load Parameters
ft·lbf

Can be obtained from the b5 pole bending-moment calculator

lbf
2Bolt Layout Parameters
in
3Verification Results
Bolt Effective Cross-Sectional Area A_e (mm²)
SizeM16M20M24M30
A_e157245353561
Property Class Design Values (ksi)
Class4.86.88.8
Tension f_t24.734.858.0
Shear f_v20.325.436.3

📋 Reference Standards

EN 1993-1-8Bolted Connections
EN 1090-2Execution of Steel Structures
ASTM F1554Anchor Bolts